+8619121401610 info@autuntech.com

Facebook
LinkedIn
info@autuntech.com
Shanghai Autun AutomationTechnology Co.,Ltd
  • HOME
  • ABOUT US
    • About Company
    • Our Team
    • Careers
  • BRAND
    • PEPPERL+FUCHS
      • P+F Safety Barrier
      • P+F Sensor
      • P+F Encoder
      • P+F Surge Protective Device
      • P+F Termination Board
    • SICK
      • SICK Sensor
      • SICK Coder
      • SICK Safety Laser Scanner
      • SICK Proximity Switch
    • Eaton
      • MTL Safety Barrier
      • MTL Surge Protective Device
      • Bussmann
    • IFM
    • OMRON
    • PILZ
    • TRUCK
    • SIEMENS
    • FESTO
    • SMC
    • PHOENIX CONTACT
    • Weidmuller
    • BANNER
    • Balluff
    • Baumer
    • Allen-Bradley
      • Frequency Converter
    • BECKHOFF
    • Endress+Hauser
    • Yokogawa
    • Panasonic
    • MTS
    • HoneyweII
    • Emerson
    • ASCO
    • KEYENCE
    • Leuze
    • ABB
    • CKD
    • HOKUYO
    • KOYO
    • Atlas
    • Rexroth
      • Amplifier
      • Rexroth Solenoid valve
      • Rexroth Sensor
    • Foxboro
  • NEWS
  • CONTACT US
  • INQUIRY
  • FAQ
HOME BRAND PEPPERL+FUCHS P+F Safety Barrier KFD2-RSH-1.2D.FL3 Pepperl+Fuchs Relay Mo
  • KFD2-RSH-1.2D.FL3 Pepperl+Fuchs Relay Module

KFD2-RSH-1.2D.FL3 Pepperl+Fuchs Relay Module

  • Product Item: KFD2-RSH-1.2D.FL3
Tags
KFD2-RSH-12DFL3
Share
Get a Quote Send Email PDF

Description

General specifications
Signal type Digital Output
Functional safety related parameters
Safety Integrity Level (SIL) SIL 3
Systematic capability (SC) SC 3
Performance level (PL) PL e
Supply
Connection Power Rail or terminals 14+, 15-
Rated voltage 19 ... 26.4 V DC
Input current max. 35 mA at 24 V DC , max. 44 mA at 19 V DC , with enabled internal fault detection
Power consumption < 1.7 W , includes the power consumption of the digital input , see derating curves
Input
Connection side control side
Connection terminals 7+, 8-
Pulse/Pause ratio min. 150 ms / min. 150 ms with disabled internal fault detection
min. 1 s / min. 1 s with enabled internal fault detection
Test pulse length max. 2 ms from DO card
Signal level 0-signal: -5 ... 5 V DC
1-signal: 19 ... 26.4 V DC
Rated current 0-signal: typ. 1.6 mA at 1.5 V DC; typ. 8 mA at 3 V DC (maximum leakage current DO card)
1-signal: ≥ 36 mA (minimum load current DO card)
Inrush current < 200 mA after 100 µs
Output
Connection side field side
Connection external voltage : terminals 4+/L, 5+/L, 2-/N
load : terminals 6, 3
Connectable voltage 50 ... 230 V AC
60 ... 110 V DC
Power dissipation < 3.3 W at 5 A , see derating curves
Contact loading 253 V AC/5 A/cos φ 0.7; 30 V DC/5 A resistive load , see derating curves
Minimum switch current 10 mA
Mechanical life 5 x 106 switching cycles
Line fault detection low voltage < 35 V AC
undercurrent: 10 mA AC; overcurrent: 5.5 A AC (relay energized)
breakage: 48 kΩ; short-circuit: 29 Ω (load, relay de-energized)
Fuse rating 2.5 A (scope of delivery)
max. 5 AT, recommended maximum utilization of the fuse: 80 %
Fault indication output
Connection terminals 10, 11
Contact loading 30 V DC/ 0.5 A resistive load
Reaction time < 2 s
Mechanical life 105 switching cycles
Transfer characteristics
Switching frequency < 3 Hz with disabled internal fault detection
< 0.5 Hz with enabled internal fault detection
Galvanic isolation
Input/power supply basic insulation according to IEC/EN 61010-1, rated insulation voltage 60 Veff
Input/fault indication output basic insulation according to IEC/EN 61010-1, rated insulation voltage 30 Veff
Output/other circuits reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Indicators/settings
Display elements LEDs
Control elements DIP switch
Configuration via DIP switches
Labeling space for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Low voltage
Directive 2014/35/EU EN 61010-1:2010
Machinery Directive
Directive 2006/42/EC EN 62061:2005+AC:2010+A1:2013+A2:2015 , EN/ISO 13849-1:2015
Conformity
Electromagnetic compatibility NE 21:2017 , IEC/EN 61326-3-2:2018 , EN 61326-3-1:2017
Degree of protection IEC 60529:2013
Ambient conditions
Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
Observe the temperature range limited by derating, see section derating.
Mechanical specifications
Degree of protection IP20
Connection screw terminals
Mass approx. 142 g
Dimensions 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
General information
Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Classifications

System Classcode
ECLASS 11.0 27210101
ECLASS 10.0.1 27210101
ECLASS 9.0 27210101
ECLASS 8.0 27210101
ECLASS 5.1 27210121
ETIM 8.0 EC001485
ETIM 7.0 EC001485
ETIM 6.0 EC001485
ETIM 5.0 EC001485
UNSPSC 12.1 39121543

Related Products

HiCTB32-TRI-AIISS-EL-PL Pepperl+Fuchs Termination Board

HiCTB32-TRI-AIISS-EL-PL Pepperl+Fuchs Termination Board

KFD2-SR2-EX1.W.LB | Pepperl+Fuchs | Isolated Switch Amplifier

KFD2-SR2-EX1.W.LB | Pepperl+Fuchs | Isolated Switch Amplifier

HiCTB32-HIM-RAC-SP-DI3202 Pepperl+Fuchs Termination Board

HiCTB32-HIM-RAC-SP-DI3202 Pepperl+Fuchs Termination Board

HiCTB16-SDC-24C-SC-RA Pepperl+Fuchs Termination Board

HiCTB16-SDC-24C-SC-RA Pepperl+Fuchs Termination Board

Pepperl + Fuchs UB400-12GM-E5-V1 Ultrasonic Threaded Barrel Proximity Sensor

Pepperl + Fuchs UB400-12GM-E5-V1 Ultrasonic Threaded Barrel Proximity Sensor

IFM PN7070 Pressure Sensor with Display

IFM PN7070 Pressure Sensor with Display

Product Categories

  • PEPPERL+FUCHS
    • P+F Safety Barrier
    • P+F Sensor
    • P+F Encoder
    • P+F Surge Protective Device
    • P+F Termination Board
  • SICK
    • SICK Sensor
    • SICK Coder
    • SICK Safety Laser Scanner
    • SICK Proximity Switch
  • Eaton
    • MTL Safety Barrier
    • MTL Surge Protective Device
    • Bussmann
  • IFM
  • OMRON
  • PILZ
  • TRUCK
  • SIEMENS
  • FESTO
  • SMC
  • PHOENIX CONTACT
  • Weidmuller
  • BANNER
  • Balluff
  • Baumer
  • Allen-Bradley
    • Frequency Converter
  • BECKHOFF
  • Endress+Hauser
  • Yokogawa
  • Panasonic
  • MTS
  • HoneyweII
  • Emerson
  • ASCO
  • KEYENCE
  • Leuze
  • ABB
  • CKD
  • HOKUYO
  • KOYO
  • Atlas
  • Rexroth
    • Amplifier
    • Rexroth Solenoid valve
    • Rexroth Sensor
  • Foxboro

Links

Google.comBaidu.com

Latest Post

  • Connectivity, Electronics, Automation, Assemblies & Software from Weidmuller
    Connectivity, Electronics, Automation, A
    2023-06-28
  • Weidmüller - Your Partner in Industrial Connectivity
    Weidmüller - Your Partner in Industrial
    2023-06-29
  • Weidmüller Group Announces $16.4 million Expansion in Chesterfield, Virginia
    Weidmüller Group Announces $16.4 million
    2023-06-29

Feedback

Contact Us

  • +8619121401610
  • +8619121401610
  • info@autuntech.com
  • Shanghai China

Mobile Website

Scan QR code

Scan for mobile site

Copyright © 2013-2023 Shanghai Autun AutomationTechnology Co.,Ltd All Rights Reserved. PRIVACY POLICY

WhatsApp
Phone
E-mail
Inquiry
Inquiry Us Now !
Inquiry Us Now !

  • +8619121401610
  • info@autuntech.com
  • +8619121401610
  • WeChat QR Code
  • Back to Top