ArabicArabicFrenchFrenchSpanishSpanishRussianRussianGermanGermanItalianItalianJapaneseJapaneseKoreanKoreanPortuguesePortugueseHindiHindiRomanianRomanianPolishPolishThaiThaiEnglishEnglish

+8619121401610 astalee@autuntech.com

Facebook
Twitter
Youtube
LinkedIn
Pinterest

Shanghai Autun AutomationTechnology Co.,Ltd
  • HOME
  • ABOUT US
    • About Company
    • Our Team
    • Careers
  • BRAND
    • PEPPERL+FUCHS
      • P+F Safety Barrier
      • P+F Sensor
      • P+F Encoder
      • P+F Surge Protective Device
      • P+F Termination Board
    • SICK
      • SICK Sensor
      • SICK Coder
      • SICK Safety Laser Scanner
      • SICK Proximity Switch
    • Eaton
      • MTL Safety Barrier
      • MTL Surge Protective Device
      • Bussmann
    • IFM
    • OMRON
    • PILZ
    • TRUCK
    • SIEMENS
    • FESTO
    • SMC
    • PHOENIX CONTACT
    • Weidmuller
    • BANNER
    • Balluff
    • Baumer
    • Allen-Bradley
    • BECKHOFF
    • Endress+Hauser
    • Yokogawa
    • Panasonic
    • MTS
    • HoneyweII
    • Emerson
    • ASCO
    • KEYENCE
    • Leuze
    • ABB
    • CKD
    • HOKUYO
    • KOYO
    • Atlas
  • NEWS
  • CONTACT US
  • INQUIRY
  • FAQ
HOME BRAND PEPPERL+FUCHS P+F Safety Barrier KFD2-SH-EX1.T.OP Pepperl+Fuchs Safety Ba
KFD2-SH-EX1.T.OP Pepperl+Fuchs Safety Barrier Brand New
  1. KFD2-SH-EX1.T.OP Pepperl+Fuchs Safety Barrier Brand New

KFD2-SH-EX1.T.OP Pepperl+Fuchs Safety Barrier Brand New

KFD2-SH-EX1TOP
Send Inquiry Live chat PDF

Description

General specifications
Signal type Digital Input
Functional safety related parameters
Safety Integrity Level (SIL) SIL 3
Performance level (PL) PL d
Supply
Connection Power Rail or terminals 14+, 15-
Rated voltage 20 ... 30 V DC
Ripple ≤ 10 %
Rated current ≤ 100 mA
Power dissipation 1.5 W
Power consumption max. 1.7 W
Input
Connection side field side
Connection terminals 4+, 6-
Open circuit voltage/short-circuit current approx. 8.4 V DC / approx. 11.7 mA
Lead resistance max. 50 Ω , cable capacitances and inductances must be observed in hazardous areas
Switching point
Relay de-energized I < 2.1 mA and I > 5.9 mA , output switched off
Relay energized 2.8 mA < I < 5.3 mA , output switched on
Response delay ≤ 1 ms
Output
Connection side control side
Connection output I: terminals 7+, 8- ; output II: terminals 9, 10 ; output III: terminals 11, 12
Output I active voltage output, short-circuit proof
0-signal: 0 V
1-signal: 19 V DC at 15 mA ... 31 V DC at no-load
fault: 0 V
Output II relay
Contact loading 48 V AC/DC
250 mA
Mechanical life ≤ 20 x 106 switching cycles
Output III relay , fault signal
Contact loading 48 V AC/DC
250 mA
Mechanical life ≤ 20 x 106 switching cycles
Transfer characteristics
Switching frequency
Output I ≤ 50 Hz
Output II ≤ 5 Hz
Output III ≤ 5 Hz
Indicators/settings
Display elements LEDs
Labeling space for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Machinery Directive
Directive 2006/42/EC EN/ISO 13849-1:2015
Conformity
Electromagnetic compatibility NE 21:2017 , EN 61326-3-2:2008
Degree of protection IEC 60529:2001
Safety IEC/EN 61508:2010
Ambient conditions
Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protection IP20
Connection screw terminals
Mass approx. 150 g
Dimensions 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection with hazardous areas
EU-type examination certificate PTB 00 ATEX 2041
Marking Ex-Hexagon II (1)G [Ex ia Ga] IIC , Ex-Hexagon II (1)D [Ex ia Da] IIIC
Input Ex ia
Voltage 9.56 V
Current 16.8 mA
Power 41 mW (linear characteristic)
Supply
Maximum safe voltage 40 V AC/DC (Attention! The rated voltage can be lower.)
Output
Contact loading 48 V AC/DC
250 mA
Maximum safe voltage 60 V AC/DC (Attention! The rated voltage can be lower.)
Certificate TÜV 99 ATEX 1493 X
Marking Ex-Hexagon II 3G Ex ec nC IIC T4 Gc
Galvanic isolation
Input/Output safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Input/power supply safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 2014/34/EU EN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN IEC 60079-15:2019
International approvals
IECEx approval
IECEx certificate IECEx PTB 21.0010
IECEx TUN 19.0013X
IECEx marking [Ex ia Ga] IIC
[Ex ia Da] IIIC
Ex ec nC IIC T4 Gc
General information
Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Classifications

System Classcode
ECLASS 11.0 27210121
ECLASS 10.0.1 27210121
ECLASS 9.0 27210121
ECLASS 8.0 27210121
ECLASS 5.1 27210121
ETIM 8.0 EC001485
ETIM 7.0 EC001485
ETIM 6.0 EC001485
ETIM 5.0 EC001485
UNSPSC 12.1 32101514

Related Products

Pepperl+Fuchs NBN8-12GM50-E0 Inductive sensor

Pepperl+Fuchs NBN8-12GM50-E0 Inductive sensor

Switch Amplifier KCD2-SOT-Ex1.LB.SP

Switch Amplifier KCD2-SOT-Ex1.LB.SP

Switch Amplifier KCD2-SON-Ex2.R2

Switch Amplifier KCD2-SON-Ex2.R2

KFD2-UT2-Ex1-1 Pepperl+Fuchs Universal Temperature Converter

KFD2-UT2-Ex1-1 Pepperl+Fuchs Universal Temperature Converter

KFD0-CS-2.51P Pepperl+Fuchs Current Driver/Repeater

KFD0-CS-2.51P Pepperl+Fuchs Current Driver/Repeater

KFD2-SOT3-EX1.LB.IO | Pepperl+Fuchs | Switch Amplifier

KFD2-SOT3-EX1.LB.IO | Pepperl+Fuchs | Switch Amplifier

Product Categories

  • PEPPERL+FUCHS
    • P+F Safety Barrier
    • P+F Sensor
    • P+F Encoder
    • P+F Surge Protective Device
    • P+F Termination Board
  • SICK
    • SICK Sensor
    • SICK Coder
    • SICK Safety Laser Scanner
    • SICK Proximity Switch
  • Eaton
    • MTL Safety Barrier
    • MTL Surge Protective Device
    • Bussmann
  • IFM
  • OMRON
  • PILZ
  • TRUCK
  • SIEMENS
  • FESTO
  • SMC
  • PHOENIX CONTACT
  • Weidmuller
  • BANNER
  • Balluff
  • Baumer
  • Allen-Bradley
  • BECKHOFF
  • Endress+Hauser
  • Yokogawa
  • Panasonic
  • MTS
  • HoneyweII
  • Emerson
  • ASCO
  • KEYENCE
  • Leuze
  • ABB
  • CKD
  • HOKUYO
  • KOYO
  • Atlas

Links

Google.comBaidu.com

LatestPost

  • Connectivity, Electronics, Automation, Assemblies & Software from Weidmuller
    Connectivity, Electronics, Automation, A
    2023-06-28
  • Weidmüller - Your Partner in Industrial Connectivity
    Weidmüller - Your Partner in Industrial
    2023-06-29
  • Weidmüller Group Announces $16.4 million Expansion in Chesterfield, Virginia
    Weidmüller Group Announces $16.4 million
    2023-06-29

Feedback

Contact Us

+8619121401610

+8619121401610

astalee@autuntech.com

Shanghai China

MOBILE WEBSITE

Copyright © 2013-2023 Shanghai Autun AutomationTechnology Co.,Ltd All Rights Reserved. PRIVACY POLICY

  • Skype.
  • E-mail
  • Whatsapp
  • Inquiry
Inquiry Us Now !
Inquiry Us Now !