ArabicArabicFrenchFrenchSpanishSpanishRussianRussianGermanGermanItalianItalianJapaneseJapaneseKoreanKoreanPortuguesePortugueseHindiHindiRomanianRomanianPolishPolishThaiThaiEnglishEnglish

+8619121401610 astalee@autuntech.com

Facebook
Twitter
Youtube
LinkedIn
Pinterest

Shanghai Autun AutomationTechnology Co.,Ltd
  • HOME
  • ABOUT US
    • About Company
    • Our Team
    • Careers
  • BRAND
    • PEPPERL+FUCHS
      • P+F Safety Barrier
      • P+F Sensor
      • P+F Encoder
      • P+F Surge Protective Device
      • P+F Termination Board
    • SICK
      • SICK Sensor
      • SICK Coder
      • SICK Safety Laser Scanner
      • SICK Proximity Switch
    • Eaton
      • MTL Safety Barrier
      • MTL Surge Protective Device
      • Bussmann
    • IFM
    • OMRON
    • PILZ
    • TRUCK
    • SIEMENS
    • FESTO
    • SMC
    • PHOENIX CONTACT
    • Weidmuller
    • BANNER
    • Balluff
    • Baumer
    • Allen-Bradley
    • BECKHOFF
    • Endress+Hauser
    • Yokogawa
    • Panasonic
    • MTS
    • HoneyweII
    • Emerson
    • ASCO
    • KEYENCE
    • Leuze
    • ABB
    • CKD
    • HOKUYO
    • KOYO
    • Atlas
  • NEWS
  • CONTACT US
  • INQUIRY
  • FAQ
HOME BRAND PEPPERL+FUCHS P+F Safety Barrier KCD2-SLD-Ex1.1245 Pepperl+Fuchs Soleno
KCD2-SLD-Ex1.1245  Pepperl+Fuchs  Solenoid Driver
  1. KCD2-SLD-Ex1.1245  Pepperl+Fuchs  Solenoid Driver

KCD2-SLD-Ex1.1245 Pepperl+Fuchs Solenoid Driver

KCD2-SLD-Ex11245
Send Inquiry Live chat PDF

Description

General specifications
Signal type Digital Output
Functional safety related parameters
Safety Integrity Level (SIL) SIL 3
Systematic capability (SC) SC 3
Supply
Connection terminals 5+, 6- loop powered
Power Rail or terminals 9+, 10- bus powered
Rated voltage 19 ... 30 V DC
loop powered
Input current 75 mA at 24 V , 270 Ω load
Power dissipation 1.3 W at 24 V , 270 Ω load
Input
Connection side control side
Connection terminals 5+, 6-
Test pulse length max. 2 ms from DO card
Signal level loop powered
1-signal: 19 ... 30 V DC
0-signal: 0 ... 5 V DC
bus powered
1-signal: 15 ... 30 V DC (current limited at 5 mA)
0-signal: 0 ... 5 V DC
Rated current 0-signal: typ. 1.6 mA at 1.5 V DC; typ. 8 mA at 3 V DC (maximum leakage current DO card)
1-signal: ≥ 36 mA (minimum load current DO card)
Inrush current < 200 mA , 10 ms loop powered
Output
Connection side field side
Connection terminals 1+, 2-
Internal resistor 240 Ω
Current typ. 45 mA
Voltage typ. 12 V
Current limit 50 mA
Open loop voltage typ. 24.6 V
Load nominal 0.05 ... 18 kΩ
Output II fault signal
Connection terminals 7, 8 , non-intrinsically safe
Contact loading 30 V DC/ 0.5 A resistive load
Mechanical life 105 switching cycles
Energized/De-energized delay ≤ 20 ms / ≤ 20 ms
Line fault detection signal at short-circuit Rload < 25 Ω, lead breakage Rload > 50 kΩ ; test current < 500 µA
Galvanic isolation
Output/other circuits basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output II/power supply basic insulation according to IEC/EN 61010-1, rated insulation voltage 32 Veff
Indicators/settings
Display elements LEDs
Control elements DIP switch
Configuration via DIP switches
Labeling space for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Conformity
Electromagnetic compatibility NE 21:2012 , EN 61326-3-2:2008
For further information see system description.
Degree of protection IEC 60529:2013
Protection against electrical shock EN 61010-1:2010
Ambient conditions
Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
Observe the temperature range limited by derating, see section derating.
Mechanical specifications
Degree of protection IP20
Connection screw terminals
Mass approx. 150 g
Dimensions 12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch) (W x H x D) , housing type A2
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection with hazardous areas
EU-type examination certificate EXA 17 ATEX 0002 X
Marking Ex-Hexagon II 3(1)G Ex nC ec [ia Ga] IIC T4 Gc
Ex-Hexagon II (1)D [Ex ia Da] IIIC
Ex-Hexagon I (M1) [Ex ia Ma] I
Output I Ex ia
Voltage 26 V
Current 110 mA
Power 715 mW
Supply
Maximum safe voltage 60 V (Attention! The rated voltage can be lower.)
Input
Maximum safe voltage 60 V (Attention! The rated voltage can be lower.)
Collective error message
Maximum safe voltage 60 V (Attention! The rated voltage can be lower.)
Galvanic isolation
Output I/other circuits safe electrical isolation acc. to IEC/EN 60079-11, rated insulation voltage 300 Vrms
Directive conformity
Directive 2014/34/EU EN 60079-0:2012+A11:2013 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
UL approval E106378
Control drawing 116-0448 (cULus)
IECEx approval
IECEx certificate IECEx EXA 17.0001X
IECEx marking Ex nC ec [ia Ga] IIC T4 Gc
[Ex ia Da] IIIC
[Ex ia Ma] I
General information
Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Classifications

System Classcode
ECLASS 11.0 27210190
ECLASS 10.0.1 27210190
ECLASS 9.0 27210190
ECLASS 8.0 27210190
ECLASS 5.1 27210121
ETIM 8.0 EC001485
ETIM 7.0 EC001485
ETIM 6.0 EC001485
ETIM 5.0 EC001485
UNSPSC 12.1 39121008

Related Products

KEYENCE CZ-K1P in stock and ready to ship

KEYENCE CZ-K1P in stock and ready to ship

Inductive sensor P+F NBN40-L2-A2-V1-M

Inductive sensor P+F NBN40-L2-A2-V1-M

KFD0-CS-Ex1.51P  Pepperl+Fuchs  Current Driver/Repeater

KFD0-CS-Ex1.51P Pepperl+Fuchs Current Driver/Repeater

Inductive sensor NBB20-U1-Z2 PEPPERL FUCHS

Inductive sensor NBB20-U1-Z2 PEPPERL FUCHS

PEPPERL FUCHS Switch Amplifier KFA6-SR2-Ex2.W.IR

PEPPERL FUCHS Switch Amplifier KFA6-SR2-Ex2.W.IR

KFD2-RSH-1.2E.L2 Pepperl+Fuchs Relay Module

KFD2-RSH-1.2E.L2 Pepperl+Fuchs Relay Module

Product Categories

  • PEPPERL+FUCHS
    • P+F Safety Barrier
    • P+F Sensor
    • P+F Encoder
    • P+F Surge Protective Device
    • P+F Termination Board
  • SICK
    • SICK Sensor
    • SICK Coder
    • SICK Safety Laser Scanner
    • SICK Proximity Switch
  • Eaton
    • MTL Safety Barrier
    • MTL Surge Protective Device
    • Bussmann
  • IFM
  • OMRON
  • PILZ
  • TRUCK
  • SIEMENS
  • FESTO
  • SMC
  • PHOENIX CONTACT
  • Weidmuller
  • BANNER
  • Balluff
  • Baumer
  • Allen-Bradley
  • BECKHOFF
  • Endress+Hauser
  • Yokogawa
  • Panasonic
  • MTS
  • HoneyweII
  • Emerson
  • ASCO
  • KEYENCE
  • Leuze
  • ABB
  • CKD
  • HOKUYO
  • KOYO
  • Atlas

Links

Google.comBaidu.com

LatestPost

  • Connectivity, Electronics, Automation, Assemblies & Software from Weidmuller
    Connectivity, Electronics, Automation, A
    2023-06-28
  • Weidmüller - Your Partner in Industrial Connectivity
    Weidmüller - Your Partner in Industrial
    2023-06-29
  • Weidmüller Group Announces $16.4 million Expansion in Chesterfield, Virginia
    Weidmüller Group Announces $16.4 million
    2023-06-29

Feedback

Contact Us

+8619121401610

+8619121401610

astalee@autuntech.com

Shanghai China

MOBILE WEBSITE

Copyright © 2013-2023 Shanghai Autun AutomationTechnology Co.,Ltd All Rights Reserved. PRIVACY POLICY

  • Skype.
  • E-mail
  • Whatsapp
  • Inquiry
Inquiry Us Now !
Inquiry Us Now !