ArabicArabicFrenchFrenchSpanishSpanishRussianRussianGermanGermanItalianItalianJapaneseJapaneseKoreanKoreanPortuguesePortugueseHindiHindiRomanianRomanianPolishPolishThaiThaiEnglishEnglish

+8619121401610 astalee@autuntech.com

Facebook
Twitter
Youtube
LinkedIn
Pinterest

Shanghai Autun AutomationTechnology Co.,Ltd
  • HOME
  • ABOUT US
    • About Company
    • Our Team
    • Careers
  • BRAND
    • PEPPERL+FUCHS
      • P+F Safety Barrier
      • P+F Sensor
      • P+F Encoder
      • P+F Surge Protective Device
      • P+F Termination Board
    • SICK
      • SICK Sensor
      • SICK Coder
      • SICK Safety Laser Scanner
      • SICK Proximity Switch
    • Eaton
      • MTL Safety Barrier
      • MTL Surge Protective Device
      • Bussmann
    • IFM
    • OMRON
    • PILZ
    • TRUCK
    • SIEMENS
    • FESTO
    • SMC
    • PHOENIX CONTACT
    • Weidmuller
    • BANNER
    • Balluff
    • Baumer
    • Allen-Bradley
    • BECKHOFF
    • Endress+Hauser
    • Yokogawa
    • Panasonic
    • MTS
    • HoneyweII
    • Emerson
    • ASCO
    • KEYENCE
    • Leuze
    • ABB
    • CKD
    • HOKUYO
    • KOYO
    • Atlas
  • NEWS
  • CONTACT US
  • INQUIRY
  • FAQ
HOME BRAND PEPPERL+FUCHS P+F Safety Barrier KFU8-UFT-Ex2.D Frequency Converter with
KFU8-UFT-Ex2.D Frequency Converter with Direction and Synchronization Monitor
  1. KFU8-UFT-Ex2.D Frequency Converter with Direction and Synchronization Monitor

KFU8-UFT-Ex2.D Frequency Converter with Direction and Synchronization Monitor

KFU8-UFT-Ex2D
Send Inquiry Live chat PDF

Description

General specifications
Signal type Digital Input
Supply
Connection terminals 23, 24
Rated voltage 20 ... 90 V DC / 48 ... 253 V AC 50 ... 60 Hz
Rated current approx. 130 mA
Power dissipation 2.2 W / 3.5 VA
Power consumption 2.5 W / 5 VA
Interface
Programming interface programming socket
Input
Connection side field side
Connection input I: terminals 1+, 3-
input II: terminals 4+, 6-
input III: terminals 13+, 14- (control input 1)
input IV: terminals 15+, 14- (control input 2)
Input I, II 2-wire sensor, sensor acc. to EN 60947-5-6 (NAMUR) or mechanical contact
Open circuit voltage/short-circuit current 8.2 V / 10 mA
Pulse duration min. 250 µs , overlap on direction of rotation signal: ≥ 125 µs
Input frequency rotation direction monitoring 0.001 ... 1000 Hz slip monitoring 10 ... 1000 Hz
Line fault detection breakage I ≤ 0.15 mA; short-circuit I > 6.5 mA
Input III, IV
Active/Passive I > 4 mA (for min. 100 ms) / I < 1.5 mA
Open circuit voltage/short-circuit current 18 V / 5 mA
Output
Connection side control side
Connection output I: terminals 10, 11, 12
output II: terminals 16, 17, 18
output III: terminals 19+, 20-
output IV: terminals 21+, 20-
output V: terminals 7-, 8+
Output I, II signal , relay
Contact loading 250 V AC / 2 A / cos φ ≥ 0.7 ; 40 V DC / 2 A
Mechanical life 5 x 107 switching cycles
Energized/De-energized delay approx. 20 ms / approx. 20 ms
Output III and IV signal , electronic output, passive
Contact loading 40 V DC
Signal level 1-signal: (L+) -2.5 V (50 mA, short-circuit/overload proof)
0-signal: switched off (off-state current ≤ 10 µA)
Output V analog
Current range 0 ... 20 mA or 4 ... 20 mA
Open loop voltage max. 24 V DC
Load max. 650 Ω
Fault signal downscale I ≤ 3.6 mA, upscale I ≥ 21.5 mA (acc. NAMUR NE43)
Transfer characteristics
Input I and II
Measurement range 0.001 ... 1000 Hz
Resolution slip monitoring: 1% frequency measurement: 0,1% of measured value; but >0.001Hz
Accuracy slip monitoring: 1% frequency measurement: 0.5% of measured value; but >0.001Hz
Measuring time frequency measurement: < 100 ms
Influence of ambient temperature 0.003 %/K (30 ppm)
Output I, II
Response delay ≤ 200 ms
Output V
Resolution < 10 µA
Accuracy < 30 µA
Influence of ambient temperature 0.005 %/K (50 ppm)
Accuracy 0.1 %
Galvanic isolation
Input I, II/other circuits reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Input III, IV/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output I, II/other circuits reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Mutual output I, II, III reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Mutual output I, II, IV reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output III, IV/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output III, IV/input III, IV basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff
Output III, IV/V basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff
Output V/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Interface/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Interface/output III, IV basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff
Indicators/settings
Display elements LEDs , display
Control elements Control panel
Configuration via operating buttons
via PACTware
Labeling space for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Low voltage
Directive 2014/35/EU EN 61010-1:2010
Conformity
Electromagnetic compatibility NE 21:2006
Degree of protection IEC 60529:2001
Input EN 60947-5-6:2000
Ambient conditions
Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protection IP20
Connection screw terminals
Mass 300 g
Dimensions 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) (W x H x D) , housing type C2
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection with hazardous areas
EU-type examination certificate TÜV 99 ATEX 1471
Marking Ex-Hexagon II (1)G [Ex ia Ga] IIC
Ex-Hexagon II (1)D [Ex ia Da] IIIC
Ex-Hexagon I (M1) [Ex ia Ma] I
Supply
Maximum safe voltage 253 V AC / 125 V DC (Attention! Um is no rated voltage.)
Input I and II terminals 1+, 3-; 4+, 6-: Ex ia
Voltage Uo 10.1 V
Current Io 13.5 mA
Power Po 34 mW (linear characteristic)
Input III and IV terminals 13+, 14-; 15+, 14- non-intrinsically safe
Maximum safe voltage Um 40 V (Attention! Um is no rated voltage.)
Output I, II terminals 10, 11, 12; 16, 17, 18 non-intrinsically safe
Maximum safe voltage 253 V (Attention! The rated voltage can be lower.)
Contact loading 253 V AC/2 A/cos φ > 0.7; 40 V DC/2 A resistive load (TÜV 99 ATEX 1471)
Output III and IV terminals 19, 20, 21 non-intrinsically safe
Maximum safe voltage Um 40 V (Attention! Um is no rated voltage.)
Output V terminals 8+, 7- non-intrinsically safe
Maximum safe voltage Um 40 V DC (Attention! Um is no rated voltage.)
Interface RS 232
Maximum safe voltage 40 V (Attention! Um is no rated voltage.)
Galvanic isolation
Input I, II/other circuits safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 2014/34/EU EN IEC 60079-0:2018 , EN 60079-11:2012
International approvals
FM approval
Control drawing 16-538FM-12
IECEx approval
IECEx certificate IECEx TUN 04.0007
IECEx marking [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
General information
Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Classifications

System Classcode
ECLASS 11.0 27210128
ECLASS 10.0.1 27210128
ECLASS 9.0 27210128
ECLASS 8.0 27210190
ECLASS 5.1 27210121
ETIM 8.0 EC002918
ETIM 7.0 EC002918
ETIM 6.0 EC002918
ETIM 5.0 EC002475
UNSPSC 12.1 39121007

Related Products

Power Supply KFA6-STR-1.24.4 PEPPERL FUCHS

Power Supply KFA6-STR-1.24.4 PEPPERL FUCHS

KFD2-STC5-Ex1.H Pepperl+Fuchs SMART Transmitter Power Supply

KFD2-STC5-Ex1.H Pepperl+Fuchs SMART Transmitter Power Supply

KFD2-SL2-Ex2.B Pepperl+Fuchs Solenoid Driver

KFD2-SL2-Ex2.B Pepperl+Fuchs Solenoid Driver

PEPPERL FUCHS Switch Amplifier KFA6-SR2-Ex2.W.IR

PEPPERL FUCHS Switch Amplifier KFA6-SR2-Ex2.W.IR

KFD2-STV4-Ex1.2O-2 Pepperl+Fuchs SMART Transmitter Power Supply

KFD2-STV4-Ex1.2O-2 Pepperl+Fuchs SMART Transmitter Power Supply

Switch Amplifier KCD2-SR-Ex2-AB

Switch Amplifier KCD2-SR-Ex2-AB

Product Categories

  • PEPPERL+FUCHS
    • P+F Safety Barrier
    • P+F Sensor
    • P+F Encoder
    • P+F Surge Protective Device
    • P+F Termination Board
  • SICK
    • SICK Sensor
    • SICK Coder
    • SICK Safety Laser Scanner
    • SICK Proximity Switch
  • Eaton
    • MTL Safety Barrier
    • MTL Surge Protective Device
    • Bussmann
  • IFM
  • OMRON
  • PILZ
  • TRUCK
  • SIEMENS
  • FESTO
  • SMC
  • PHOENIX CONTACT
  • Weidmuller
  • BANNER
  • Balluff
  • Baumer
  • Allen-Bradley
  • BECKHOFF
  • Endress+Hauser
  • Yokogawa
  • Panasonic
  • MTS
  • HoneyweII
  • Emerson
  • ASCO
  • KEYENCE
  • Leuze
  • ABB
  • CKD
  • HOKUYO
  • KOYO
  • Atlas

Links

Google.comBaidu.com

LatestPost

  • Connectivity, Electronics, Automation, Assemblies & Software from Weidmuller
    Connectivity, Electronics, Automation, A
    2023-06-28
  • Weidmüller - Your Partner in Industrial Connectivity
    Weidmüller - Your Partner in Industrial
    2023-06-29
  • Weidmüller Group Announces $16.4 million Expansion in Chesterfield, Virginia
    Weidmüller Group Announces $16.4 million
    2023-06-29

Feedback

Contact Us

+8619121401610

+8619121401610

astalee@autuntech.com

Shanghai China

MOBILE WEBSITE

Copyright © 2013-2023 Shanghai Autun AutomationTechnology Co.,Ltd All Rights Reserved. PRIVACY POLICY

  • Skype.
  • E-mail
  • Whatsapp
  • Inquiry
Inquiry Us Now !
Inquiry Us Now !