ArabicArabicFrenchFrenchSpanishSpanishRussianRussianGermanGermanItalianItalianJapaneseJapaneseKoreanKoreanPortuguesePortugueseHindiHindiRomanianRomanianPolishPolishThaiThaiEnglishEnglish

+8619121401610 astalee@autuntech.com

Facebook
Twitter
Youtube
LinkedIn
Pinterest

Shanghai Autun AutomationTechnology Co.,Ltd
  • HOME
  • ABOUT US
    • About Company
    • Our Team
    • Careers
  • BRAND
    • PEPPERL+FUCHS
      • P+F Safety Barrier
      • P+F Sensor
      • P+F Encoder
      • P+F Surge Protective Device
      • P+F Termination Board
    • SICK
      • SICK Sensor
      • SICK Coder
      • SICK Safety Laser Scanner
      • SICK Proximity Switch
    • Eaton
      • MTL Safety Barrier
      • MTL Surge Protective Device
      • Bussmann
    • IFM
    • OMRON
    • PILZ
    • TRUCK
    • SIEMENS
    • FESTO
    • SMC
    • PHOENIX CONTACT
    • Weidmuller
    • BANNER
    • Balluff
    • Baumer
    • Allen-Bradley
    • BECKHOFF
    • Endress+Hauser
    • Yokogawa
    • Panasonic
    • MTS
    • HoneyweII
    • Emerson
    • ASCO
    • KEYENCE
    • Leuze
    • ABB
    • CKD
    • HOKUYO
    • KOYO
    • Atlas
  • NEWS
  • CONTACT US
  • INQUIRY
  • FAQ
HOME BRAND PEPPERL+FUCHS P+F Safety Barrier Switch Amplifier KFD2-SR3-Ex2.2S
Switch Amplifier KFD2-SR3-Ex2.2S
  1. Switch Amplifier KFD2-SR3-Ex2.2S

Switch Amplifier KFD2-SR3-Ex2.2S

KFD2-SR3-Ex22S
Send Inquiry Live chat PDF

Description

General specifications
Signal type Digital Input
Functional safety related parameters
Safety Integrity Level (SIL) SIL 2
Systematic capability (SC) SC 3
Supply
Connection Power Rail or terminals 14+, 15-
Rated voltage 19 ... 30 V DC
Ripple ≤ 10 %
Rated current 30 ... 20 mA
Power consumption < 600 mW
Input
Connection side field side
Connection terminals 1+, 2+, 3-; 4+, 5+, 6-
Rated values acc. to EN 60947-5-6 (NAMUR)
Open circuit voltage/short-circuit current approx. 10 V DC / approx. 8 mA
Switching point/switching hysteresis 1.2 ... 2.1 mA / approx. 0.2 mA
Line fault detection breakage I ≤ 0.1 mA , short-circuit I ≥ 6.5 mA
Pulse/Pause ratio min. 20 ms / min. 20 ms
Output
Connection side control side
Connection output I: terminals 7, 8 ; output II: terminals 8, 9 ; output III: terminals 10, 11 ; output IV: terminals 11, 12
Output I, II, III, IV channel 1, 2; relay
Contact loading 48 V AC/1 A/cos φ > 0.7; 40 V DC/1 A resistive load
Minimum switch current 1 mA / 24 V DC
Energized/De-energized delay approx. 20 ms / approx. 20 ms
Mechanical life 108 switching cycles
Collective error message Power Rail
Transfer characteristics
Switching frequency ≤ 10 Hz
Galvanic isolation
Input/Output reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Input/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output/power supply basic insulation according to IEC/EN 61010-1, rated insulation voltage 32 Veff , functional insulation, rated insulation voltage 50 Veff
Output/Output basic insulation according to IEC/EN 61010-1, rated insulation voltage 32 Veff , functional insulation, rated insulation voltage 50 Veff
Indicators/settings
Display elements LEDs
Control elements DIP switch
Configuration via DIP switches
Labeling space for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Conformity
Electromagnetic compatibility NE 21:2012 , EN 61326-3-2:2008
Degree of protection IEC 60529:2001
Input EN 60947-5-6:2000
Ambient conditions
Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protection IP20
Connection screw terminals
Mass approx. 150 g
Dimensions 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection with hazardous areas
EU-type examination certificate EXA 16 ATEX 0001 X
Marking Ex-Hexagon II 3(1)G Ex nA nC [ia Ga] IIC T4 Gc
Ex-Hexagon II (1)D [Ex ia Da] IIIC
Ex-Hexagon I (M1) [Ex ia Ma] I
Input Ex ia
Voltage 10.5 V
Current 17.1 mA
Power 45 mW (linear characteristic)
Supply
Maximum safe voltage 250 V AC (Attention! Um is no rated voltage.)
Output
Maximum safe voltage 250 V AC (Attention! The rated voltage can be lower.)
Galvanic isolation
Input/Output safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Input/power supply safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 2014/34/EU EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
UL approval E106378
Control drawing 116-0423 (cULus)
IECEx approval
IECEx certificate IECEx EXA 16.0001X
IECEx marking Ex nA nC [ia Ga] IIC T4 Gc , [Ex ia Da] IIIC , [Ex ia Ma] I
General information
Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Classifications

System Classcode
ECLASS 11.0 27210121
ECLASS 10.0.1 27210121
ECLASS 9.0 27210121
ECLASS 8.0 27210121
ECLASS 5.1 27210121
ETIM 8.0 EC001485
ETIM 7.0 EC001485
ETIM 6.0 EC001485
ETIM 5.0 EC001485
UNSPSC 12.1 32101514

Related Products

MTL4521 Loop Powered Solenoid Alarm Driver

MTL4521 Loop Powered Solenoid Alarm Driver

HiCTB16-YC3-RRB-KS-CC-AM16-Y2 Pepperl+Fuchs Termination Board

HiCTB16-YC3-RRB-KS-CC-AM16-Y2 Pepperl+Fuchs Termination Board

KFD2-RSH-1.2E.L2 Pepperl+Fuchs Relay Module

KFD2-RSH-1.2E.L2 Pepperl+Fuchs Relay Module

Switch Amplifier KCD2-SR-Ex1.LB.SP

Switch Amplifier KCD2-SR-Ex1.LB.SP

Sick DL50-P1123 Displacement Sensors 1047361

Sick DL50-P1123 Displacement Sensors 1047361

HiATB01-HART-4X8 Pepperl+Fuchs HART Communication Board

HiATB01-HART-4X8 Pepperl+Fuchs HART Communication Board

Product Categories

  • PEPPERL+FUCHS
    • P+F Safety Barrier
    • P+F Sensor
    • P+F Encoder
    • P+F Surge Protective Device
    • P+F Termination Board
  • SICK
    • SICK Sensor
    • SICK Coder
    • SICK Safety Laser Scanner
    • SICK Proximity Switch
  • Eaton
    • MTL Safety Barrier
    • MTL Surge Protective Device
    • Bussmann
  • IFM
  • OMRON
  • PILZ
  • TRUCK
  • SIEMENS
  • FESTO
  • SMC
  • PHOENIX CONTACT
  • Weidmuller
  • BANNER
  • Balluff
  • Baumer
  • Allen-Bradley
  • BECKHOFF
  • Endress+Hauser
  • Yokogawa
  • Panasonic
  • MTS
  • HoneyweII
  • Emerson
  • ASCO
  • KEYENCE
  • Leuze
  • ABB
  • CKD
  • HOKUYO
  • KOYO
  • Atlas

Links

Google.comBaidu.com

LatestPost

  • Connectivity, Electronics, Automation, Assemblies & Software from Weidmuller
    Connectivity, Electronics, Automation, A
    2023-06-28
  • Weidmüller - Your Partner in Industrial Connectivity
    Weidmüller - Your Partner in Industrial
    2023-06-29
  • Weidmüller Group Announces $16.4 million Expansion in Chesterfield, Virginia
    Weidmüller Group Announces $16.4 million
    2023-06-29

Feedback

Contact Us

+8619121401610

+8619121401610

astalee@autuntech.com

Shanghai China

MOBILE WEBSITE

Copyright © 2013-2023 Shanghai Autun AutomationTechnology Co.,Ltd All Rights Reserved. PRIVACY POLICY

  • Skype.
  • E-mail
  • Whatsapp
  • Inquiry
Inquiry Us Now !
Inquiry Us Now !